ELMo 120 Multiplexer installation and testin
g
2-17
Revision 2.01 ELMo 120 Multiplexer Installation and Maintenance Guide 08-01023-01
Task:
Installing ELMo 120 Multiplexer connections for
voice/data service
Use this procedure to connect the ELMo 120 Multiplexer to the EtherLoop
cross-connect in voice/data applications.
Requirements
This procedure requires the following tools and materials:
10-ELMo 120 Multiplexer cable harnesses
10-intermediate cables
10-ELMo 120 Multiplexer data jumper cables
Appendix B contains the specifications for the cables and wiring required in
this procedure.
Action
Step Action
1
Place and secure the dedicated EtherLoop cross-connect blocks on the
facility main distribution frame.
2
Desi
g
nate and label one side of each block as "Line/CPE", and the other side
as "Voice."
3
Connect one Amp-Champ connector of an intermediate cable to the to the
"Line/CPE" side of the EtherLoop cross-connect block, and route the other
connector to the equipment bay containin
g
the voiceband filter shelf.
4
Connect the Amp-Champ connector of a second intermediate cable to the
"Voice" side of the EtherLoop cross-connect block, and route the other
connector to the equipment bay containin
g
the voiceband filter shelf.
—continued—